Chemical Fume Hood SGS Tested Complying with ASHRAE110-2016
description1
description2
Performance of Chemical Safety Fume Hood

Test data shows Zero Leakage 0.00 ppm tested at face velocity 0.5m/s, according to ASHRAE110-2016 US standard.
OSHA report released in 1990 revealed a following fact:
● The average lifetime of laboratory personnel is 10 years less than that of normal people!
● The reason directly refers to: Leakage rate of the fume hood in the laboratory.
● The real safety index of the fume hood is the leakage rate, not the face velocity!
Evolution of Leakage Rate Standard of Fume Hood
Standard |
Stipulated Leakage Rate |
1985 USA ASHRAE110-1985 |
0.5 PPM |
1995 USA ASHRAE110-1995 |
0.05 PPM |
Product Features of Fume Hood in Chemistry
1. By optimizing the structure of the fume cupboard and combining aerodynamics theory, the working chamber of fume hood can maintain smooth airflow under working conditions, reduce turbulence and reverse airflow and improve the overall safety of the product.
2. Particularly designed exhaust canopy on the top of fume hood,made of special fire-resistant material and it helps exhaust noxious air effectively and completely.
3. With specially designed arc aluminum alloy handle satisfying smooth airflow entry to working chamber.
Detailed Description of Chemical Fume Hood
Type |
FC1200 |
FC1500 |
FC1800 |
|
Exterior size(LxWxH) |
1200*850*2350mm |
1500*850*2350mm |
1800*850*2350mm |
|
Interior size(LxWxH) |
920*630*1180mm |
1220*630*1180mm |
1520*630*1180mm |
|
Working height |
850mm |
|||
Material |
Cold-rolled or galvanized steel coated with Akzonobel anti-corrosive epoxy resin powder. |
|||
Lining: 5mm phenolic resin panel/ceramic fiber panel, chemical resistant and easy to be dismantled and cleaned without tool. | ||||
Worktop: 19mm thick solid epoxy resin with 25mm thick water proof edge/ceramic/ lab grade phenolic resin etc. | ||||
Sash: two pcs of 5mm toughened safety glass, with high quality long aluminum handle. Height can be moved up and down freely and it can be stopped at any position. | ||||
Sash max opening |
780mm |
|||
Power supply |
220/380V, 50/60Hz, single or three phase |
|||
Noise |
<65dB |
|||
Air face velocity |
Average 0.3~0.5m/s |
|||
Illumination |
>400 LUX, LED lighting, insulated from air by tempered glass |
|||
Diameter of exhaust outlet |
250mm |
|||
Standard accessories |
LCD controller,LED lamp, brand remote water and gas fittings with safety function, 4 universal sockets, leakage protector, emergency botton, PP cup sink etc. |
|||
Optional accessories |
Centrifugal fan, 3 meters of PVC flexible pipe, France digital controller with sensor, VAV system, motorized sash, grid frame etc. |
|||
Packing size |
Upper cabinet |
1250*900*1650mm |
1550*900*1650mm |
1850*900*1650mm |
Base cabinet |
1250*570*1000mm |
1250*570*1000mm |
1250*570*1000mm |
Remark:
Storage cabinet
Door: double-layers structure with sound absorbing material inside,keeping noise minimum when door is opened or closed. U-shape128mm 304 stainless steel handle, long aluminum alloy grab handle. Acid and inflammable cabinets are available.
Color: White, gray, blue or specified by customer

Accessories of Fume Hood

Standard: Ashrae110-2016, SEFA8M-2016
SGS Test Report
